Phone number:0086-0577-61731588
Fax:0086-0577-61731588
Cell phone:+86 18072180777
Wechat:+86 18072180777
Website:www.china-relay.com
Zhiguang Industrial Zone, Liu Town, Yueqing, Zhejiang, China
Summarize
NDS15P series digital time relay (hereinafter referred to as relay) is suitable for ac 50Hz, working voltage 380V and below or DC working voltage 24V control circuit as a delay element, according to the predetermined time to switch on or off the circuit.
The relay is set as digital dialing code, which completely replaces ST3P, AH2, AH3 series products, and solves the defect of nonlinearity adjustment of potentiometer of ST3P, AH2, AH3 series products, and can be widely used for delay control in automatic control circuit.
This series of relays implements Q/ZND 0081 enterprise standard, in accordance with GB 14048.5 and JB/T 10047 related provisions.
Main technical parameters
Model |
NDS15P |
NDS15PG |
NDS15PC |
NDS15PF |
NDS15PA |
NDS15PK |
NDS15PY |
NDS15PR |
Working mode |
Delay on |
Release time delay |
Power delay with transient contact |
Delay off |
Delay on |
Signal disconnection delay |
Star Triangle start delay |
Reciprocating cycle delay |
Delay range |
0.1s~9.9s、0.1s~99.9s、1s~99s、1s~999s、10s~990s、0.1m~9.9m、1m~99m、0.1h~9.9h、1h~99h |
0.1s~9.9s 1s~99s |
0.1~9.9s、1s~99s、0.1m~9.9m、1m~99m、0.1h~9.9h、1h~99h共6种延时规格可调 |
|||||
Set way |
2 /3 digit dial-code switch Settings |
2 digit digital dial code switch setting, 1 bit base dial code switch setting |
||||||
Repetitive error |
When the delay range is greater than 1s, Er≤1% : when the delay range is less than 1s, Dr≤50ms |
|||||||
Contact number |
Delay 2 conversion |
Delay one conversion Transient 1 conversion
|
Delay 2 conversion |
A. Delay 2 conversion B. Delay 1 conversion, transient 1 conversion |
Delay one conversion |
Delay star triangulation, transient 1 normally open |
Delay one conversion |
|
Contact capacity |
AC250V 3A COSØ=1 |
|||||||
Electrical life |
1X105次 |
|||||||
The rated voltage |
AC24V、AC36V、AC110V、AC220V、AC380V 50Hz,DC24V; Allowable fluctuation range(85%~110%)Ue |
|||||||
The environment temperature |
-5℃~40℃ |
|||||||
At an altitude of |
≤2000m |
|||||||
humidity |
When the maximum temperature at the installation site is 40℃, the relative humidity of the air shall not exceed 50%, and higher humidity may be allowed at lower temperatures, such as 90℃ at 20℃.Special measures should be taken for occasional condensation due to temperature changes |
|||||||
installation |
With different sockets and accessories, device type, panel type and 35mm guide rail installation can be realized |
Working sequence diagram
The wiring diagram
Outline size drawing (mm)
Directions for use
1. Connect the product to the control circuit according to the wiring diagram on the label of relay housing and refer to the example of circuit Article 8.
2. Adjust the dial code switch, premake the delay time, turn on the power, and the relay starts to run according to the corresponding working sequence in the third article
3. NDS15PF power on time should be ≥ 2S.
4. When the NDS15PK signal control end (3 and 4) is closed, it shall be more than 50ms. From the time when the control end (3 and 4) is disconnected, the relay shall start to delay and delay to the preset time, and the relay shall release.
5. NDS15PA mode A and B can be selected by adjusting the shift switch on the panel, and the delay time and Mode A and B should be set before the product is powered on.
6. The delay time of NDS15PY star triangle conversion is 70ms.
Message feedback
News Center
Naidian Group is an electronic timer manufacturer and digital timer supplier, providing high-power relays, electronic time relays, digital timer relays, DC to AC solid state relays, and digital display timer relay knowledge popularization.
On February 26, the production of NPOWER Group resumed. The director and manager of our company personall...
Time: December 5th - December 7th, 2024. Booth No.: 5P66, Hall N5 Add: Halls N1 - N5 and W5, Shanghai New...
There are five main advantages of choosing a time relay, namely, Control voltage, Functional requirements...
Time relays are usually used in circuits with lower voltage or lower current to control circuits with hig...
GET A QUOTE