AC 220V Electronic Time Relay NDS15A C G Y(ST3PA C G Y)

AC 220V Electronic time relay NDS15A C G Y(ST3PA C G Y) is suitable for ac 50Hz, working voltage 380V and below or DC working voltage 24V control circuit as a delay element, according to the predetermined time to switch on or off the circuit.

AC 220V Electronic Time Relay NDS15A C G Y(ST3PA C G Y)  Summarize

NDS15 series super time relay (hereinafter referred to as relay) is suitable for ac 50Hz, working voltage 380V and below or DC working voltage 24V control circuit as a delay element, according to the predetermined time to switch on or off the circuit.
This relay is a new product introduced from Fuji Electric co., LTD., which has the advantages of small size, light weight, high precision, wide delay range, good performance and long life, etc., and can be widely used in automatic control circuit for delay control.
This series relay conforms to gb140485-2000 and JB/T 10047-1999 standard, and implements Q/NDL 10021-2000 enterprise standard.

An electronic time relay is a device that is used to control the timing of electronic circuits. It is designed to provide precise timing functions, such as delaying an action or turning an action on or off after a certain time period. It functions based on a predetermined set time and can be programmed to perform various timing functions based on the specific application.

Electronic time relays typically consist of several components, including a microcontroller or timing circuit, input and output terminals, and a control interface. The microcontroller or timing circuit is responsible for keeping track of time and controlling the relay's operation. The input terminals allow for external signals or triggers to start or stop the timing cycle, while the output terminals control the switching of the circuit based on the timing parameters.

The control interface of an electronic time relay allows the user to set the desired timing parameters, such as the delay time or the on/off duration. Depending on the specific model, the control interface can be a simple dial or buttons for manual adjustment, or it can be a digital display or programming interface for more precise and complex timing configurations.

Electronic time relays are commonly used in various industries and applications, such as industrial automation, control systems, process control, and equipment monitoring. They provide accurate timing control, allowing for automation and synchronization of processes for improved efficiency and functionality.

 Main technical parameters

Model

NDS15A

NDS15G

NDS15C

NDS15F

NDS15F-2

NDS15K

NDS15Y

NDS15R

Action form

Electricity delay

Release time delay

Power delay with transient

contact

Power o

ff

delay

Signal

disconnection

delay

Star

Triangle

start delay

Reciprocating

cycle delay

Delay time

range

A:0.05~0.5s/5s/30s/3min

B:0.1s~1s/10s/60s/6min

C:0.5~5s/50s/5min/30min

D:1~10s/100s/10min/60min

E:5~60s/10min/60min/6h

F:0.25~2min/20min/2h/12h

G:0.5~4min/40min/4h/24h

0.1-1s

0.2-2s

0.5-5s

1-10s

2.5-30s

5-60s

 

0.1-0.5s

0.25-2s

0.5-5s

1-10s

2.5-30s

5-60s

 

1-10s

2.5-30s

5-60s

 

0.5-6s / 60s

1-10s / 10min

2.5-30s /

30min

 

Setting

method

Potentiometer

Repeated

errors

≤1%

≤5%

≤1%

Contact

quantity

Delay 2 Z

 

Delay one Z 

Transient 1 Z

 

Delay one Z 

 

Delay two Z

 

Delayed

triangulation

transient

1 NO

 

Delay one Z 

 

Contact

capacity

AC250V 3A COSФ=1

 

Mechanical

life

1×1000000 Times

 

Electric Life

1×100000 Times

 

Rated

Voltage

AC24V, 110V, 220V 50Hz;

DC24V, 48V,110V

AC110V,

220V 50Hz

DC24V

AC110V, 220V 50HZ

AC110V,

220V, 50HZ,

DC24V

Mounting

type

With different sockets and accessories, device type, panel type and 35mm guide rail installation can be realized

 

Working sequence diagram

c g y st3pa c g y dzssjjdq 6c g y st3pa c g y dzssjjdq 7

The wiring diagram

c g y st3pa c g y dzssjjdq 8

 

Outline and installation dimension drawing

Message feedback

News Center

Naidian Group is an electronic timer manufacturer and digital timer supplier, providing high-power relays, electronic time relays, digital timer relays, DC to AC solid state relays, and digital display timer relay knowledge popularization.

Return to work in the disease

On February 26, the production of NPOWER Group resumed. The director and manager of our company personall...

The 32nd Shanghai International Electric Power Equipment and Technology Exhibition (EP Shanghai 2024)

Time: December 5th - December 7th, 2024. Booth No.: 5P66, Hall N5 Add: Halls N1 - N5 and W5, Shanghai New...

What are the key points in selecting a time relay?

There are five main advantages of choosing a time relay, namely, Control voltage, Functional requirements...

What is the future development trend of time relay?

Time relays are usually used in circuits with lower voltage or lower current to control circuits with hig...

GET A QUOTE

Get in Touch
×