Click volume: 1099 Release time: 2021-04-14

The influence of the environment on the reliability of the relay: The average time between failures of the relay working in GB and SF is the highest, reaching 820000h, while in the NU environment, it is only 60000h.
The effect of quality level on the reliability of relays: when the relay of A1 quality level is selected, the mean time between failures can reach 360,000h, while the average time between failures of the C-level relay is 110000, which is 33 times the difference. It can be seen that the quality level of the relay is The impact of its reliability performance is very large.
The influence of the contact form on the reliability of the relay: The contact form of the relay will also affect its reliability. The reliability of single-throw relays is higher than that of double-throw relays with the same number of poles. At the same time, it is reliable as the number of poles increases. The performance is gradually decreasing, and the mean time between failures of single-pole single-throw relays is 5.5 times that of four-pole double-throw relays.
The influence of structure type on the reliability of relay: There are 24 types of relay structure, and different types all have an impact on its reliability.
The influence of temperature on the reliability of the relay: The operating temperature range of the relay is between -25 and 70°C. As the temperature increases, the relay's mean time between failures gradually decreases.
The effect of the action rate on the reliability of the relay: With the increase of the action rate of the relay, the mean time between failures basically shows an exponential downward trend. Therefore, if the designed circuit requires a very high rate of action of the relay, it is necessary to carefully check the relay in order to replace it in time when the circuit is repaired.
The influence of current ratio on the reliability of the relay: The so-called current ratio is the ratio of the working load current of the relay to the rated load current. The current ratio has a great influence on the reliability of the relay, especially when the current ratio is greater than 0.1, the mean time between failures drops rapidly, and when the current ratio is less than 0.1, the mean time between failures is basically the same, so the rated current should be selected in the circuit design Larger load to reduce the current ratio, so as to ensure that the relay and even the entire circuit will not reduce the reliability due to the fluctuation of the operating current.

-END-

News Recommendations

Naidian Group is an electronic timer manufacturer and digital timer supplier, providing high-power relays, electronic time relays, digital timer relays, DC to AC solid state relays, and digital display timer relay knowledge popularization.

What is electronic time relay?

An electronic time relay is an electronic control device that can automatically control system timing and...

Explanation of the meaning, the working principle, and types of time relay

Electrical control is a method of automatic or remote control of mechanical equipment using the structure...

Relay manufacturers share the difference between relays and circuit breakers, contactors, switches, solid-state relays, mechanical relays, and ordinary relays

Relay manufacturers share the difference between relays and circuit breakers, contactors, switches, solid...

How to measure the quality of circuit board relays? How to wire it?

How to measure the quality of circuit board relays?Measure with a multimeter. You can measure the resista...

GET A QUOTE

Get in Touch
Captcha Code
×