TCD/TCR Series Digital Display Temperature Controller
TCD/TCR Series Digital Display Temperature Controller

TCD/TCR Series digital display temperature controller

Supply voltage :220V 50/60Hz
Allowable voltage variation range: 90-110% of supply voltage
Power consumed: below 5VA
Display accuracy :±0.3% control
Sampling period :50ms
Relay life: machinery more than 2.5 million times

Type

tcrxl sxswdkzq 02

Specification

The power supply voltage

220V  50/60Hz

Range of allowable voltage variation

90-110% of the supply voltage

Consumed power

Under 5VA

Input specification

Thermocouple

K  E  J

The thermal resistance

Pt100  Cu50

Display precision

± 0.3%

Control the output

Relay 250VAC 5A  1NO1NC

The control mode

ON/OFF stepping control

Time proportional control

 

RESET adjustment range.

0~10℃

Sampling period

50ms

Relay life

Mechanical more than 2.5 million times

Electrical more than 100,000 times

Withstand voltage

3000VAC  50/60Hz 1 min (between terminal and housing)

Resistance to vibration

5~55Hz(period: 1 minute) amplitude  0.75mm  X,Y,Z

Two hours in each direction

Insulation impedance

More than 100 m Ω (500 VDC megohm benchmark)

Anti-interference

Square wave interference (pulse width  1μm) generated

 by the interference generator ±2KV R phase S phase

Power failure memory

About 10 years (non-volatile semiconductor mode)

The surrounding environment

Operating ambient temperature

When stored at -5~40℃ : -10~50℃

Ambient humidity in use

35~85% storage :35 ~85%

The wiring diagram

tcrxl sxswdkzq 03

Operation

tcrxl sxswdkzq 04

Temperature setting and control

1. ON/OFF control: After the power supply is powered ON, set the required temperature setting value and start operation.When the actual temperature value is lower than the set value, the ON green light will be ON, and the normal opening point of the output relay will be ON, and the normal closing point will be off.When the actual value reaches or exceeds the set value, the OFF red light will be on and the normal opening point of the output relay will be disconnected and the normal closing point will be connected.
2. When the time ratio is controlled, after the power is powered on, set the required temperature setting value and start the operation.When the actual temperature does not enter the proportional band, the ON green light will be ON, and the normally open point of the output relay will be ON, and the normally closed point will be off.When entering the proportional band, the relay starts to switch regularly. The higher the temperature is, the shorter the output time is, and vice versa. The temperature is controlled by changing the average heating power of the load.
3, the use of the panel "RESET" potentiometer: when the time proportional control heating system balance, due to the load heating power of large or small, the actual value is lower than the set value of the static difference correction, adjust the potentiometer can eliminate the deviation, to adapt to different working conditions.

Fault message indication

Message

Instructions

Elimination method

HHH

Input disconnected or out of range

Please check the input signal for error

LLL

Input disconnected or out of range

Please check the input signal for error

Attention

1. In order to eliminate inductive interference, please wire the product separately with high-voltage lines, power lines, etc.
2.Use the M3 terminal in the following shape.

tcrxl sxswdkzq 05

3. Please use the power switch or circuit breaker when turning off the power to the product.
4. Please install the switch and circuit breaker nearby for the operator to operate.
5. If the product is used as temperature indication or adjustment, it should not be used as other instruments.
6. When using the thermal resistance (RTD) sensor, 3 wires should be connected. If you want to extend the wire, you must use the same type and length of wire connection.If the impedance of the line is different, it may cause temperature deviation.
7. When the power line and the input signal line have to be installed closer, please add a filter at the power end and shield the signal line.
8. Keep away from high frequency equipment (high frequency welder, high frequency sewing machine, high capacity SCR controller)
9. When the measurement input is switched on, HHH or LLL will be displayed if any error occurs. At this time, check whether the input is wrong after power off.
10. This product is used in the following environments.
①indoor                                                                         ②pollution level 2 (pollution degree2)
③The Installation category ll is below 2000m.              ④Installation category ll
※If you violate the above precautions, it may cause product failure. Please be sure to comply.

Message feedback

News Center

Naidian Group is an electronic timer manufacturer and digital timer supplier, providing high-power relays, electronic time relays, digital timer relays, DC to AC solid state relays, and digital display timer relay knowledge popularization.

Return to work in the disease

On February 26, the production of NPOWER Group resumed. The director and manager of our company personall...

The 32nd Shanghai International Electric Power Equipment and Technology Exhibition (EP Shanghai 2024)

Time: December 5th - December 7th, 2024. Booth No.: 5P66, Hall N5 Add: Halls N1 - N5 and W5, Shanghai New...

What are the key points in selecting a time relay?

There are five main advantages of choosing a time relay, namely, Control voltage, Functional requirements...

What is the future development trend of time relay?

Time relays are usually used in circuits with lower voltage or lower current to control circuits with hig...

GET A QUOTE

Get in Touch
×