产品中心
NDA3-(HHA3-1) Electronic load limiting automatic controller
NDA3-(HHA3-1) Electronic load limiting automatic controller

NDA3-(HHA3-1) Electronic load limiting automatic controller

Operating voltage :AC220V 50Hz
Protective action current: 0.5A, 1A, 3A, 4A, 5A, 6A, 7A, 8A, 
                                        10A, 12A, 14A, 16A, 20A, 25A, 32A 
                                        (other specifications can be customized).
Protection action delay time: 4S ~ 6S (1.2 times) has the inverse time limit characteristic.
Reset mode: automatic reset (20s ~ 60s)
Protection action current error: ±10%.
Power consumption: WL5W.
Electric life: 1X10°.
External dimension :(80x50x66.5) mm.
Installation: 35mm guideway installation

Summarize

NDA3-1 (HHA3-1) series electronic load limiting automatic controller (hereinafter referred to as controller) is suitable for ac 50Hz, working voltage AC220V control circuit, according to the rated power supply.When the electric load exceeds the specified range value, the controller automatically cuts off the load power supply to realize automatic control.The use of control occasions mainly for industrial and mining, enterprise employee dormitory, construction site migrant workers dormitory, control of employees, workers illegal use of electricity to achieve the purpose of safe use.Compact structure, beautiful appearance, and DZ47 (C45) parallel installation.

Directions for use

1. Correctly connect the input terminal (IN) and output terminal (OUT) according to the product identification (the load current should be less than the protection current value of the product).
2. Indicator state of two-color light emitting diode on the panel: When the indicator lamp emits green light, the load power supply is switched on and in running state;When it's red.The protection function is started and the load power is cut off.
3. The load limiting (current) protection action of the controller has the inverse time limit characteristic;That is, when the load exceeds the protection current value of the product, the longer the protection action time of the product is, and vice versa.

Attention

1. Before switching on the power, please carefully check whether the wiring is correct, whether the load size matches the current protection value of the product, and whether the wiring screw has been tightened, otherwise the product will be damaged..
2. After the product is connected to the power supply, do not contact the live part to avoid electric shock.
3. Because the product has no short circuit protection function, when there is short circuit at the input end or the load end of the product, the load limit protection function cannot be started and the product will be damaged.
4. Since the product is reset automatically, when the offending electrical equipment is connected, the controller should dial down the offending electrical equipment immediately after the protection tripping, otherwise the controller will reset and disconnect frequently, thus damaging the product and the electrical equipment.
5. In order to prevent contact heating under strong current, the screws of the terminal must be tightened when wiring, otherwise the product will be damaged or other accidents will be caused by heating at the terminal caused by excessive contact resistance.

Installation method

nda3 1dzxhzdkzq 03

Application circuit example

Direct control wiring: The controlled appliances are single-phase power supply, and the power consumption does not exceed the rated capacity of the controller.The direct control method can be adopted, and the wiring method is shown in the figure below.

nda3 1dzxhzdkzq 04

Ordering Instructions:

The product model, product protection current specification, voltage class and quantity shall be explained. If there is any special requirement, it shall be indicated separately.Cases (100 nDA3-120A AC220V).

Main technical data

Operating voltage :AC220V 50Hz
Protective action current: 0.5A, 1A, 3A, 4A, 5A, 6A, 7A, 8A, 10A, 12A, 14A, 16A, 20A, 25A, 32A (other specifications can be customized).
Protection action delay time: 4S ~ 6S (1.2 times) has the inverse time limit characteristic.
Reset mode: automatic reset (20s ~ 60s)
Protection action current error: ±10%.
Power consumption: WL5W.
Electric life: 1X10°.
External dimension :(80x50x66.5) mm.
Installation: 35mm guideway installation

The wiring diagram

nda3 1dzxhzdkzq 01

Installation dimension drawing

nda3 1dzxhzdkzq 02

Message feedback

News Center

Naidian Group is an electronic timer manufacturer and digital timer supplier, providing high-power relays, electronic time relays, digital timer relays, DC to AC solid state relays, and digital display timer relay knowledge popularization.

Return to work in the disease

On February 26, the production of NPOWER Group resumed. The director and manager of our company personall...

The 32nd Shanghai International Electric Power Equipment and Technology Exhibition (EP Shanghai 2024)

Time: December 5th - December 7th, 2024. Booth No.: 5P66, Hall N5 Add: Halls N1 - N5 and W5, Shanghai New...

What are the key points in selecting a time relay?

There are five main advantages of choosing a time relay, namely, Control voltage, Functional requirements...

What is the future development trend of time relay?

Time relays are usually used in circuits with lower voltage or lower current to control circuits with hig...

GET A QUOTE

Get in Touch
×