Phone number:0086-0577-61731588
Fax:0086-0577-61731588
Cell phone:+86 18072180777
Wechat:+86 18072180777
Website:www.china-relay.com
Zhiguang Industrial Zone, Liu Town, Yueqing, Zhejiang, China
Contact forms :2Z, 2H, 2D, 3Z, 3H, 3D, 4Z, 4H, 4D
Contact resistance: 100 m or less Ω (1 a 6 VDC)
Shock load :10A 250VAC/30VDC
Insulation resistance: 500 m or more Ω (500 VDC)
Operation time :≤25ms/25ms
Socket mode: circuit board and socket mounting
Rated coil power :DC/AC 0.9W/1.2VA
Specifications
Contact form |
2D 2H 2Z |
3D 3H 3Z |
4D 4H 4Z |
Contact resistance |
≤100mΩ(1A 6VDC) |
||
Contact metal |
AgCdO AgSnO2 |
||
The contact load |
10A 250VAC/30VDC |
||
Insulation resistance |
≥500MΩ(500VDC) |
||
Insulation Voltage ≥ |
BCC 1500VAC 1min |
||
BOC 1000VAC 1min |
|||
Contact between groups≥1500VAC 1min |
|||
Actuation/Release Time |
≤25ms/25ms |
||
Socket model |
Circuit Board and Socket Mounting |
Coil parameters
Coil rating |
DC/AC 0.9W/1.2VA |
DC Coil Specification Table
Rated Voltage (VDC) |
Suction Voltage (VDC) |
Release Voltage (VDC) |
Coil Resistance Ω: ±10% |
5 |
4.0 |
0.5 |
28 |
6 |
4.8 |
0.6 |
40 |
12 |
9.6 |
1.2 |
160 |
24 |
19.2 |
2.4 |
640 |
48 |
38.4 |
4.8 |
2560 |
110 |
88.0 |
11.0 |
12100 |
AC Coil Specification Table
Rated Voltage (VDC) |
Suction Voltage (VDC) |
Release Voltage (VDC) |
Coil Resistance Ω: ±10% |
6 |
4.8 |
1.8 |
12 |
12 |
9.6 |
3.6 |
42 |
24 |
19.2 |
7.2 |
168 |
48 |
38.4 |
14.4 |
675 |
110 |
96.0 |
36.0 |
3500 |
220/240 |
176.0 |
66.0 |
14000/16500 |
Outline size; Wiring diagram (below)
HH62P
HH63P
HH64P
Message feedback
News Center
Naidian Group is an electronic timer manufacturer and digital timer supplier, providing high-power relays, electronic time relays, digital timer relays, DC to AC solid state relays, and digital display timer relay knowledge popularization.
On February 26, the production of NPOWER Group resumed. The director and manager of our company personall...
Time: December 5th - December 7th, 2024. Booth No.: 5P66, Hall N5 Add: Halls N1 - N5 and W5, Shanghai New...
There are five main advantages of choosing a time relay, namely, Control voltage, Functional requirements...
Time relays are usually used in circuits with lower voltage or lower current to control circuits with hig...
GET A QUOTE