Phone number:0086-0577-61731588
Fax:0086-0577-61731588
Cell phone:+86 18072180777
Wechat:+86 18072180777
Website:www.china-relay.com
Zhiguang Industrial Zone, Liu Town, Yueqing, Zhejiang, China
Ratings: DC 220V, 110V, 48V
Delay setting range: a) 20 Ms-9.999s (level difference 1ms)
b) 0.1-99.99s (level difference 10ms)
c) 1 S-999.9s (level difference 0.1s)
d) 10 S-9999 s(level difference 1s)
Return time: Return time should be no more than 25 msPower consumption: At rated voltage, the power consumption of the relay shall not be greater than that specified in Table
Usage
SS-94 time relay is used as a delay control element in secondary circuit relay protection circuit and automatic control of power system.It is suitable for the occasions with high time measurement precision and small time difference.
Type name of relay
The type of relay and the meanings it represents are as follows:
Working principle and internal wiring
1.The working principle of
This relay is static digital time relay, which is composed of imported CMOS integrated circuit, using frequency division and counting principle to realize delay time.The standard clock pulse is produced by a quartz crystal oscillator.After the rated voltage is applied, the internal transient relay moves and exits to make the crystal vibrate at the same time, generating clock pulse. After frequency division, the clock pulse is counted by the counter. When the measured pulse number reaches the time delay, the flip-flop flips to drive and execute the relay action exit.The principle block diagram of the relay is shown in Figure 1
2.Wiring diagram behind the relay (see Figure 2)
FIG. 2 Backside wiring diagram of relay
Installation, use and maintenance
1.Installation
Single relay for embedded installation
2.Use
a)Pay attention to voltage specification and positive voltage when using.Negative polarity;
b)The working environment conditions of the product shall be satisfied;
3.Maintenance
The product should be inspected regularly. First, the appearance should be checked to see if the solder joints of the printed circuit board fall off, and if the wires are folded.Secondly, check whether the DC circuit is working normally.
Contact number and form
Model |
Delay loop T 1 output contact |
Delay loop T 1 output contact |
Delay loop T 1 output contact |
SS- 94 / 1 |
NO |
1Z |
NO |
SS- 94 / 2 |
NO |
1Z |
1Z |
SS- 94 / 3 |
1Z |
1Z |
NO |
SS- 94 / 4 |
1Z |
1Z |
1Z |
The delay range and delay level difference of the product
Delay range code |
Delay range |
Delay xmax-xmin range |
1 |
20ms-9.999s |
1ms |
2 |
0.1s-99.99s |
10ms |
3 |
1s-999.9s |
0.1s |
4 |
10s-9999s |
1s |
Working environment conditions
The product shall work reliably under the following conditions a) Ambient temperature: -10 ℃-+ 50℃
b) Atmospheric pressure: 80 K PA-110 k Pa
c) Relative temperature: The average maximum relative temperature of the wettest month is 90%. Meanwhile, the average temperature of the month is 25℃ and there is no condensation on the surface. When the highest temperature is 40℃, the average maximum relative temperature does not exceed 50%;
d) An environment free of conductive dust and corrosive gases that destroy metals and insulation;
e) There is no explosion risk and medium without dust (such as coal ash, abrasive, sawdust, etc.);
f) Working position: tilt not more than 5° in any direction and no severe vibration and impact;
g) The site shall be equipped with rainproof, snow, wind and sand devices and an environment without water vapor;
h) Where there is no more serious mold;
i) Strong external magnetic induction is not allowed in the place of use.Delay range
Technical data
1. Ratings: DC 220 V, 110 V, 48 V
2.Delay setting range
a) 20 Ms-9.999s (level difference 1ms)
b) 0.1-99.99s (level difference 10ms)
c) 1 S-999.9s (level difference 0.1s)
d) 10 S-9999 s(level difference 1s)
3.Operation value and return value Under the reference condition, the operation voltage of the relay shall not be greater than 70% rated voltage, and the return voltage shall not be less than 10% rated voltage.
4.Delay consistency Under the reference condition, the delay consistency of the relay is not greater than (0.1 % setting value + 3 ms).Delay consistency = maximum value of 5 measurements - minimum value of 5 measurements
5.Under the reference condition, the absolute value of the relay's delay setting error is not greater than (0.1 % setting value + 3 ms) delay average error = the average value of 5 measurements - setting value
6.Return time: Return time should be no more than 25 ms
7.Power consumption: At rated voltage, the power consumption of the relay shall not be greater than that specified in Table
Table 3 Power consumption of relay
Rated Voltage |
Before the action |
After the action |
22 V |
7 W |
12 W |
110 V |
5 W |
8 W |
48 V |
4 W |
6 W |
8. Contact performance
In A dc inductive load circuit with voltage no more than 250 V and current no more than 1 A (time constant 5 ms+ 0.75 ms), the contact disconnection capacity is 30 W.
9. Dielectric strength
The electrical terminals of the relay shall be connected to the exposed non-charged metal parts or housing, and shall be able to withstand the test of 2 K V(effective value) 50 Hz AC voltage for 1 min without insulation breakdown or flashering phenomenon.
Appearance and hole size
The relay adopts an embedded insert structure. See figure 3 attached to this manual for its appearance and installation hole size.
Message feedback
News Center
Naidian Group is an electronic timer manufacturer and digital timer supplier, providing high-power relays, electronic time relays, digital timer relays, DC to AC solid state relays, and digital display timer relay knowledge popularization.
On February 26, the production of NPOWER Group resumed. The director and manager of our company personall...
There are five main advantages of choosing a time relay, namely, Control voltage, Functional requirements...
Time relays are usually used in circuits with lower voltage or lower current to control circuits with hig...
GET A QUOTE